Capacitance Meter UA6013L Auto Range Digital LCD Capacitor Test Multimeter Measurement Tester Meter
Professional Capacitance Meter UA6013L Auto Range Digital LCD Capacitor Test Multimeter Measurement Tester Meter
It is a professional capacitance meter with wide measuring range, stable performance and accuracy result. With large LCD display and white backlight, easy to read.
6013L type digital capacitance meter is pocket, convenient operation, accurate numerical reading, low-consumption, driven by battery, and showing numbers in a big LCD. Being accurate in measuring, it covers 9 measuring sections, a wide rang from 0.1pF to 20,000μF. It can be used in testing error testing, numerical analysis, selecting capacitance, measuring unknown capacitance, matching capacitance, and measuring the capacitance of cable, switch and printing electrocircuit.
It is applied with CMOS double-bevel A/D convertor that is automatic in zeroing and polar selection, and makes instruction for beyond measuring range.
Wide measuring range, covering 9 measuring sections from 0.1pF to 20,000μF that includes nominal value of any capacitance.
Biggest display value: 1999(3 1/2).
Reading: 2-3 readings/sec.
Zeroing: There is a zeroing knob on the front, easy for operation.
Data hold: Put the “HOLD” switch to “ON” and the DH sign will appear on the display.
Temperature for accurate measuring: 25±5°C
Temperature range: working temperature: 0 to 40°C
Storage temperature: -10to 50°C
Relative humidity: <80%
Power supply:9V laminated battery(Not included)
Features:
This meter can be used to measure capacitance of cable and switch.
Applied with CMOS double-bevel A/D convertor that is automatic in zeroing and polar selection.
Wide measuring range, data hold function, it is more practical.
Large LCD display with white backlight, easy to read.
Maximum display value: 1999(3 1/2).
Low battery indication.
Note:
Please ensure that all measured capacitor are discharged before testing.
Specifications:
Measuring Range: 200pF / 2nF / 20nF / 200nF / 2μF / 20μF / 200μF / 2000μF / 20mF
Accuracy: ±0.5%±20digit(200pF/2nF/20nF/200nF/2μF/20μF/200μF) / ±2.0%±20digit(2000μF) / ±4.0%±20digit(20mF)
Resolution: 0.1pF / 1pF / 10pF / 0.1nF / 1nF / 10nF / 0.1μF / 1 μF / 10μF
Testing Frequency: 800Hz(200pF/2nF/20nF/200nF/2μF) / 80Hz(20μF) / 8Hz(200μF/2000μF/20mF)
Power Supply: 1 * 9V Battery (not included)
Item Size: 14.5 * 7 * 3cm / 5.7 * 2.7 * 1.2in
Item Weight: 144g / 5.1oz
Package Size: 19.5 * 11 * 5cm / 7.7 * 4.3 * 2in
Package Weight: 215g / 7.6oz
Operation:
Firstly, check a 9V battery whether its electric voltage is short that will show signal on the left-upper of the LCD. Secondly, pay attention to the polarity or the capacitance to be tested. Thirdly, recharge the capacitance before measuring.
1. Select proper measuring section according to the capacitance to be tested.
2. Check and use the zeroing knob on the front of the meter to adjust the value to zero before measuring.
3. Insert the black sensor into the jack with “-”signal and the red sensor into the jack with “+”.
4. Connect the capacitance to be tested with the two sensors. Pay attention to the polarity of the capacitance ! Read capacitance numerical value displayed.
Notes
a. If you don’t know the approximate value of a capacitance, you should select measuring section of 200nF and then make relevant adjusting according to practical situation.
b. If the capacitance is in short circuit, the meter shows “beyond measuring range”. If the capacitance is in electric leakage, the meter shows “beyond measuring range” or “much bigger than the normal value”. If the capacitance is open-circuit, the meter shows “Zero” or “several pF “.
c. In testing small capacitance, directly insert the capacitance into the jack instead of using the sensors for better accuracy.
Maintenance
The meter is of highly accurate electronic apparatus. Don’t change its internal circuit rashly for no damage to the meter.
1. Don’t exert electric voltage upon the jack parts of the meter for no damage to the meter.
2. Don’t test the sensors in short circuit , or the battery will be consumed out quickly.
3. Don’t use a meter whose back cover doesn’t cover the meter well.
4. Always replace battery and fuse after taking sensors out of a meter that is switched off. First, screw bolts in the back cover out. Second, take off the back cover. Third, replace battery and fuse according to specification provisioned in the operation manual. Suitable fuse for this meter is 200mA/250V, which external dimension is φ5×20mm.
5. Please take out the battery when not using for a long time.
Packaging List:
1pc* Capacitance Meter UA6013L ( not include battery )